Skip to main content

CVE-2023-4346KNX Association KNX Protocol Connection Authorization Option 1 Overly Restrictive Account Lockout Mechanism Vulnerability

Patch nowHigh7.5Exploited, CISA due date 2026-07-29EPSS 1.4%, higher than 72% of scored CVEs

CVE-2023-4346 is a vulnerability in KNX Protocol Connection Authorization Option 1, rated high (7.5 on CVSS 3.1).

Why this priority: Exploited in the wild: listed in CISA's KEV catalog.

Published · Updated · NVD status: Analyzed

What it is

The record does not classify the weakness yet; the description below says what the reporter found.

How it is reached

An attacker can exploit it over the network, without an account, and nobody has to click anything.

What an attacker gains

A successful attack can take it offline.

Is it being exploited?

CISA added it to the Known Exploited Vulnerabilities catalog on 2026-07-15: it is being exploited in the wild. It can be exploited automatically, at scale. EPSS estimates a 1.4% chance of exploitation activity in the next 30 days, higher than 72% of scored CVEs.

What to do

  1. Treat it as urgent: it is on CISA's KEV list. CISA's deadline for US federal agencies: 2026-07-29.
  2. No fixed version is listed yet. Find every place KNX Protocol Connection Authorization Option 1 runs, watch the references for a fix, and plan a replacement if it is no longer supported.
  3. While there is no fix, keep it off the internet or behind a VPN, allowlist or authenticating proxy.
  4. Check exposed instances for signs of compromise, not only for the version.

Description from NVD

KNX devices that use KNX Connection Authorization and support Option 1 are, depending on the implementation, vulnerable to being locked and users being unable to reset them to gain access to the device. The BCU key feature on the devices can be used to create a password for the device, but this password can often not be reset without entering the current password. If the device is configured to interface with a network, an attacker with access to that network could interface with the KNX installation, purge all devices without additional security options enabled, and set a BCU key, locking the device. Even if a device is not connected to a network, an attacker with physical access to the device could also exploit this vulnerability in the same way.

What this means for your architecture.

A CVE names a product. Whether it matters depends on where that product sits in your systems: what reaches it, which trust boundary it guards and what it can reach once compromised. Veriom maps your components, their relationships and your trust boundaries from your code, cloud and delivery evidence, so you can see where a component like this sits. The radar itself does not look at your systems.

Components it touches

  • KNX Protocol Connection Authorization Option 1. Start from where it runs and what it is connected to.

Trust boundaries in play

  • Internet-facing entry points. No account is needed. Any instance reachable from outside your perimeter, through a load balancer, gateway, VPN or exposed admin port, is in scope.

Questions to answer about your own systems

  • Where does KNX Protocol Connection Authorization Option 1 run in your systems, and at which version?
  • Which of those instances can be reached from the internet or partner networks?
  • What can it reach once compromised: which data stores, secrets and services?

Sources

  • CVE records and CVSS scores from the NVD CVE API. This product uses the NVD API but is not endorsed or certified by the NVD.
  • Exploitation status from CISA’s Known Exploited Vulnerabilities catalog.
  • Exploit likelihood from FIRST’s Exploit Prediction Scoring System (EPSS), refreshed daily.
  • Explanations are written by Veriom from fixed templates over each record’s data, not by a person reviewing each CVE. Descriptions are quoted from the records as published.