Skip to main content

CVE-2026-106019Johnson Controls C-CURE 9000, Victor sensitive data in logs

Schedule itHigh8.8EPSS not scored yet

CVE-2026-106019 is a sensitive data in logs in Johnson Controls C-CURE 9000, Victor, rated high (8.8 on CVSS 4.0).

Why this priority: High severity, with no exploitation signal yet.

Published · Updated · NVD status: Awaiting Analysis

What it is

Secrets or personal data are written to log files.

How it is reached

An attacker can exploit it from the same local network segment, with an ordinary user account, and nobody has to click anything. Success also depends on conditions the attacker does not fully control.

What an attacker gains

A successful attack can read the data it protects, change data or behaviour and take it offline. In practice, this kind of flaw lets an attacker learn data or internals that help a follow-up attack. The damage can spread past the vulnerable component into others.

Is it being exploited?

There is no public report of exploitation yet.

What to do

  1. No fixed version is listed yet. Find every place Johnson Controls C-CURE 9000, Victor runs, watch the references for a fix, and plan a replacement if it is no longer supported.
  2. Segment the networks that can reach it.

Description from NVD

Insertion of sensitive information into log file vulnerability in Johnson Controls C-CURE 9000, Victor allows Use of Known Operating System Credentials.

This issue affects C-CURE 9000, Victor: 3.20.

What this means for your architecture.

A CVE names a product. Whether it matters depends on where that product sits in your systems: what reaches it, which trust boundary it guards and what it can reach once compromised. Veriom maps your components, their relationships and your trust boundaries from your code, cloud and delivery evidence, so you can see where a component like this sits. The radar itself does not look at your systems.

Components it touches

  • Error responses, logs and debug endpoints. The flaw sits between internal data and whoever can read the response or log.
  • APIs that over-share. The flaw sits between internal data and whoever can read the response or log.

Trust boundaries in play

  • Local network segment. The attacker must share a network segment with the target.
  • Isolation between components. The impact crosses out of the vulnerable component into others it should be isolated from.
  • Between internal data and whoever can read the response or log. An attacker who crosses it can learn data or internals that help a follow-up attack.

Questions to answer about your own systems

  • Where does Johnson Controls C-CURE 9000, Victor run in your systems, and at which version?
  • Which network segments can reach them?
  • What can it reach once compromised: which data stores, secrets and services?

Sources

  • CVE records and CVSS scores from the NVD CVE API. This product uses the NVD API but is not endorsed or certified by the NVD.
  • Exploitation status from CISA’s Known Exploited Vulnerabilities catalog.
  • Exploit likelihood from FIRST’s Exploit Prediction Scoring System (EPSS), refreshed daily.
  • Explanations are written by Veriom from fixed templates over each record’s data, not by a person reviewing each CVE. Descriptions are quoted from the records as published.