Skip to main content

CVE-2026-116779SignalWire FreeSwitch Code Injection Vulnerability

Patch nowCritical9.8Exploited, CISA due date 2026-11-12EPSS 2.2%, higher than 82% of scored CVEs

CVE-2026-116779 is a command injection in SignalWire FreeSwitch, rated critical (9.8 on CVSS 3.1).

Why this priority: Exploited in the wild: listed in CISA's KEV catalog.

Published · Updated · NVD status: Analyzed

What it is

Input ends up inside a command the software runs, so an attacker can add commands of their own. Input reaches an operating-system command line, letting an attacker run their own commands on the host.

How it is reached

An attacker can exploit it over the network, without an account, and nobody has to click anything.

What an attacker gains

A successful attack can read the data it protects, change data or behaviour and take it offline. In practice, this kind of flaw lets an attacker run commands or code with the privileges of the affected service.

Is it being exploited?

CISA added it to the Known Exploited Vulnerabilities catalog on 2026-11-09: it is being exploited in the wild. It can be exploited automatically, at scale. EPSS estimates a 2.2% chance of exploitation activity in the next 30 days, higher than 82% of scored CVEs.

What to do

  1. Treat it as urgent: it is on CISA's KEV list. CISA's deadline for US federal agencies: 2026-11-12.
  2. Upgrade SignalWire FreeSwitch to 1.11.3 or later. The patch notes are linked below.
  3. Until it is patched, keep it off the internet or behind a VPN, allowlist or authenticating proxy.
  4. Check exposed instances for signs of compromise, not only for the version.

Description from NVD

FreeSWITCH is a Software Defined Telecom Stack enabling the digital transformation from proprietary telecom switches to a software implementation that runs on any commodity hardware. Prior to 1.11.3, sofia_presence_handle_sip_i_message() split the To user of an inbound SIP MESSAGE on a plus sign and treated the left side as a chat protocol selector. Selecting the api chat proto reached switch_api_execute(), allowing a peer whose MESSAGE was accepted to run FreeSWITCH API commands, including operating-system command sinks, with the daemon's privileges. Inbound chat is enabled on the stock internal and external profiles, and any authenticated profile account is sufficient; stock directory users without password material can also remove that barrier in affected configurations. The flaw permits configuration and credential disclosure, arbitrary call control, and command execution, and exploitation has been observed in the wild. This issue is fixed in version 1.11.3.

What this means for your architecture.

A CVE names a product. Whether it matters depends on where that product sits in your systems: what reaches it, which trust boundary it guards and what it can reach once compromised. Veriom maps your components, their relationships and your trust boundaries from your code, cloud and delivery evidence, so you can see where a component like this sits. The radar itself does not look at your systems.

Components it touches

  • Application servers and the hosts they run on. The flaw sits between untrusted input and code or command execution.
  • Template engines. The flaw sits between untrusted input and code or command execution.
  • Permission checks in APIs and admin surfaces. The flaw sits between one role or tenant and another.
  • Multi-tenant services. The flaw sits between one role or tenant and another.

Trust boundaries in play

  • Internet-facing entry points. No account is needed. Any instance reachable from outside your perimeter, through a load balancer, gateway, VPN or exposed admin port, is in scope.
  • Between untrusted input and code or command execution. An attacker who crosses it can run commands or code with the privileges of the affected service.
  • Between one role or tenant and another. An attacker who crosses it can reach data or actions their role should not allow.

Questions to answer about your own systems

  • Where does SignalWire FreeSwitch run in your systems, and at which version?
  • Which of those instances can be reached from the internet or partner networks?
  • What can it reach once compromised: which data stores, secrets and services?

Sources

  • CVE records and CVSS scores from the NVD CVE API. This product uses the NVD API but is not endorsed or certified by the NVD.
  • Exploitation status from CISA’s Known Exploited Vulnerabilities catalog.
  • Exploit likelihood from FIRST’s Exploit Prediction Scoring System (EPSS), refreshed daily.
  • Explanations are written by Veriom from fixed templates over each record’s data, not by a person reviewing each CVE. Descriptions are quoted from the records as published.