CVE-2026-119293signalwire freeswitch origin validation error
CVE-2026-119293 is a origin validation error in signalwire freeswitch, rated critical (9.3 on CVSS 4.0).
Why this priority: Critical, and reachable over the network without an account.
Published · Updated · NVD status: Awaiting Analysis
What it is
The software does not check where a request or message really comes from.
How it is reached
An attacker can exploit it over the network, without an account, and nobody has to click anything.
What an attacker gains
A successful attack can take it offline. In practice, this kind of flaw lets an attacker act inside a signed-in user's browser session. The damage can spread past the vulnerable component into others.
Is it being exploited?
There is no public report of exploitation yet. It can be exploited automatically, at scale.
What to do
- Upgrade signalwire freeswitch to 1.11.2 or later.
- Until it is patched, keep it off the internet or behind a VPN, allowlist or authenticating proxy.
Description from NVD
FreeSWITCH is a Software Defined Telecom Stack enabling the digital transformation from proprietary telecom switches to a software implementation that runs on any commodity hardware. In 1.11.2 and earlier, rtp_common_read() in src/switch_rtp.c uses one session-wide autoadj_tally to learn RTP sources that differ from the address negotiated in SDP. An unauthenticated remote attacker who sends plaintext RTP during call setup can make packets from one or more non-advertised sources reach the threshold before the legitimate endpoint, causing FreeSWITCH to adopt the source of the threshold-crossing packet as the media peer. The attacker can then receive call audio, inject media, and deny media to the legitimate endpoint without being on the media path. FreeSWITCH 1.11.2 adds two opt-in controls, but both default to zero and the release remains affected unless both are configured before RTP session creation. This vulnerability is fixed in 1.11.2.
What this means for your architecture.
A CVE names a product. Whether it matters depends on where that product sits in your systems: what reaches it, which trust boundary it guards and what it can reach once compromised. Veriom maps your components, their relationships and your trust boundaries from your code, cloud and delivery evidence, so you can see where a component like this sits. The radar itself does not look at your systems.
Components it touches
- Web front ends and single-page apps. The flaw sits between a user's browser and the web application.
- Admin consoles served to a browser. The flaw sits between a user's browser and the web application.
Trust boundaries in play
- Internet-facing entry points. No account is needed. Any instance reachable from outside your perimeter, through a load balancer, gateway, VPN or exposed admin port, is in scope.
- Isolation between components. The impact crosses out of the vulnerable component into others it should be isolated from.
- Between a user's browser and the web application. An attacker who crosses it can act inside a signed-in user's browser session.
Questions to answer about your own systems
- Where does signalwire freeswitch run in your systems, and at which version?
- Which of those instances can be reached from the internet or partner networks?
- What can it reach once compromised: which data stores, secrets and services?
Read more
Advisories
Sources
- CVE records and CVSS scores from the NVD CVE API. This product uses the NVD API but is not endorsed or certified by the NVD.
- Exploitation status from CISA’s Known Exploited Vulnerabilities catalog.
- Exploit likelihood from FIRST’s Exploit Prediction Scoring System (EPSS), refreshed daily.
- Explanations are written by Veriom from fixed templates over each record’s data, not by a person reviewing each CVE. Descriptions are quoted from the records as published.