Skip to main content

CVE-2026-120387Circutor PowerStudio SCADA Wave improper signature verification

High priorityCritical10.0EPSS not scored yet

CVE-2026-120387 is a improper signature verification in Circutor PowerStudio SCADA Wave, rated critical (10.0 on CVSS 4.0).

Why this priority: Critical, and reachable over the network without an account.

Published · Updated · NVD status: Received

What it is

A cryptographic signature is not checked properly, so forged data is accepted.

How it is reached

An attacker can exploit it over the network, without an account, and nobody has to click anything.

What an attacker gains

A successful attack can read the data it protects, change data or behaviour and take it offline. In practice, this kind of flaw lets an attacker read or tamper with traffic, or pass a forged message as genuine. The damage can spread past the vulnerable component into others.

Is it being exploited?

There is no public report of exploitation yet.

What to do

  1. Upgrade Circutor PowerStudio SCADA Wave to 24.11.17.0 or later.
  2. Until it is patched, keep it off the internet or behind a VPN, allowlist or authenticating proxy.

Description from NVD

An improper JWT signature verification vulnerability in CIRCUTOR PowerStudio SCADA WAVE desktop version allows an unauthenticated remote attacker to bypass authentication by submitting an unsigned JWT with the algorithm set to “none”. The shared JWT validation component accepts the token without verifying a cryptographic signature, allowing the attacker to impersonate another user and access protected functionality with that user's privileges.

What this means for your architecture.

A CVE names a product. Whether it matters depends on where that product sits in your systems: what reaches it, which trust boundary it guards and what it can reach once compromised. Veriom maps your components, their relationships and your trust boundaries from your code, cloud and delivery evidence, so you can see where a component like this sits. The radar itself does not look at your systems.

Components it touches

  • TLS termination and service-to-service channels. The flaw sits on the network path between clients and services.
  • Signature checks. The flaw sits on the network path between clients and services.

Trust boundaries in play

  • Internet-facing entry points. No account is needed. Any instance reachable from outside your perimeter, through a load balancer, gateway, VPN or exposed admin port, is in scope.
  • Isolation between components. The impact crosses out of the vulnerable component into others it should be isolated from.
  • On the network path between clients and services. An attacker who crosses it can read or tamper with traffic, or pass a forged message as genuine.

Questions to answer about your own systems

  • Where does Circutor PowerStudio SCADA Wave run in your systems, and at which version?
  • Which of those instances can be reached from the internet or partner networks?
  • What can it reach once compromised: which data stores, secrets and services?

Sources

  • CVE records and CVSS scores from the NVD CVE API. This product uses the NVD API but is not endorsed or certified by the NVD.
  • Exploitation status from CISA’s Known Exploited Vulnerabilities catalog.
  • Exploit likelihood from FIRST’s Exploit Prediction Scoring System (EPSS), refreshed daily.
  • Explanations are written by Veriom from fixed templates over each record’s data, not by a person reviewing each CVE. Descriptions are quoted from the records as published.