Skip to main content

CVE-2026-124450openemr external control of a file name

Schedule itCritical9.3EPSS not scored yet

CVE-2026-124450 is a external control of a file name in openemr, rated critical (9.3 on CVSS 4.0).

Why this priority: Critical severity, with no exploitation signal yet.

Published · Updated · NVD status: Awaiting Analysis

What it is

Input decides which file the software opens, so a caller can point it elsewhere.

How it is reached

An attacker can exploit it over the network, with an ordinary user account, and nobody has to click anything.

What an attacker gains

A successful attack can read the data it protects and change data or behaviour. In practice, this kind of flaw lets an attacker read or write files outside the folders the service meant to expose. The damage can spread past the vulnerable component into others.

Is it being exploited?

There is no public report of exploitation yet.

What to do

  1. Upgrade openemr to 8.3.0 or later.
  2. Until it is patched, review who holds accounts that can reach it.

Description from NVD

OpenEMR before 8.3.0 contains a broken access control and path traversal vulnerability in the fax/sms module disposeDocument action via an unvalidated file_path parameter. Authenticated low-privilege users can read sqlconf.php to recover database credentials and write arbitrary files as the web user, enabling remote code execution.

What this means for your architecture.

A CVE names a product. Whether it matters depends on where that product sits in your systems: what reaches it, which trust boundary it guards and what it can reach once compromised. Veriom maps your components, their relationships and your trust boundaries from your code, cloud and delivery evidence, so you can see where a component like this sits. The radar itself does not look at your systems.

Components it touches

  • File storage the service can read or write. The flaw sits between the application and the file system it can reach.

Trust boundaries in play

  • Authenticated network access. An account is needed, so exposure follows who can sign in: customers, partners or staff.
  • Isolation between components. The impact crosses out of the vulnerable component into others it should be isolated from.
  • Between the application and the file system it can reach. An attacker who crosses it can read or write files outside the folders the service meant to expose.

Questions to answer about your own systems

  • Where does openemr run in your systems, and at which version?
  • Which of those instances can be reached from the internet or partner networks?
  • What can it reach once compromised: which data stores, secrets and services?

Sources

  • CVE records and CVSS scores from the NVD CVE API. This product uses the NVD API but is not endorsed or certified by the NVD.
  • Exploitation status from CISA’s Known Exploited Vulnerabilities catalog.
  • Exploit likelihood from FIRST’s Exploit Prediction Scoring System (EPSS), refreshed daily.
  • Explanations are written by Veriom from fixed templates over each record’s data, not by a person reviewing each CVE. Descriptions are quoted from the records as published.