CVE-2026-126977Philips Hue Bridge vulnerability
CVE-2026-126977 is a vulnerability in Philips Hue Bridge, rated high (8.1 on CVSS 3.0).
Why this priority: High severity, with no exploitation signal yet.
Published · Updated · NVD status: Received
What it is
The record does not classify the weakness yet; the description below says what the reporter found.
How it is reached
An attacker can exploit it from the same local network segment, without an account, and nobody has to click anything.
What an attacker gains
A successful attack can read the data it protects and change data or behaviour.
Is it being exploited?
There is no public report of exploitation yet.
What to do
- No fixed version is listed yet. Find every place Philips Hue Bridge runs, watch the references for a fix, and plan a replacement if it is no longer supported.
- Segment the networks that can reach it.
Description from NVD
Philips Hue Bridge HomeKit Pair-Setup Default Password Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the HomeKit Authentication service, which listens on TCP port 8080 by default. Crafted data in a pairing request can cause the device to allow authentication using a blank password. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-28323.
What this means for your architecture.
A CVE names a product. Whether it matters depends on where that product sits in your systems: what reaches it, which trust boundary it guards and what it can reach once compromised. Veriom maps your components, their relationships and your trust boundaries from your code, cloud and delivery evidence, so you can see where a component like this sits. The radar itself does not look at your systems.
Components it touches
- Philips Hue Bridge. Start from where it runs and what it is connected to.
Trust boundaries in play
- Local network segment. The attacker must share a network segment with the target.
Questions to answer about your own systems
- Where does Philips Hue Bridge run in your systems, and at which version?
- Which network segments can reach them?
- What can it reach once compromised: which data stores, secrets and services?
Sources
- CVE records and CVSS scores from the NVD CVE API. This product uses the NVD API but is not endorsed or certified by the NVD.
- Exploitation status from CISA’s Known Exploited Vulnerabilities catalog.
- Exploit likelihood from FIRST’s Exploit Prediction Scoring System (EPSS), refreshed daily.
- Explanations are written by Veriom from fixed templates over each record’s data, not by a person reviewing each CVE. Descriptions are quoted from the records as published.