Skip to main content

CVE-2026-126980Philips Hue Bridge observable discrepancy

Low priorityMedium6.5EPSS not scored yet

CVE-2026-126980 is a observable discrepancy in Philips Hue Bridge, rated medium (6.5 on CVSS 3.0).

Why this priority: Medium severity, with no exploitation signal.

Published · Updated · NVD status: Received

What it is

Different responses or timings reveal secrets, such as which accounts exist.

How it is reached

An attacker can exploit it from the same local network segment, without an account, and nobody has to click anything.

What an attacker gains

A successful attack can read the data it protects. In practice, this kind of flaw lets an attacker learn data or internals that help a follow-up attack.

Is it being exploited?

There is no public report of exploitation yet.

What to do

  1. No fixed version is listed yet. Find every place Philips Hue Bridge runs, watch the references for a fix, and plan a replacement if it is no longer supported.
  2. Segment the networks that can reach it.

Description from NVD

Philips Hue Bridge HomeKit Observable Discrepancy Information Disclosure Vulnerability. This vulnerability allows network-adjacent attackers to disclose sensitive information on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.

The specific flaw exists within the HomeKit Authentication service, which listens on TCP port 8080 by default. When processing crafted pairing requests, the service discloses internal information via an observable discrepancy between possible responses. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the device. Was ZDI-CAN-28470.

What this means for your architecture.

A CVE names a product. Whether it matters depends on where that product sits in your systems: what reaches it, which trust boundary it guards and what it can reach once compromised. Veriom maps your components, their relationships and your trust boundaries from your code, cloud and delivery evidence, so you can see where a component like this sits. The radar itself does not look at your systems.

Components it touches

  • Error responses, logs and debug endpoints. The flaw sits between internal data and whoever can read the response or log.
  • APIs that over-share. The flaw sits between internal data and whoever can read the response or log.

Trust boundaries in play

  • Local network segment. The attacker must share a network segment with the target.
  • Between internal data and whoever can read the response or log. An attacker who crosses it can learn data or internals that help a follow-up attack.

Questions to answer about your own systems

  • Where does Philips Hue Bridge run in your systems, and at which version?
  • Which network segments can reach them?
  • What can it reach once compromised: which data stores, secrets and services?

Sources

  • CVE records and CVSS scores from the NVD CVE API. This product uses the NVD API but is not endorsed or certified by the NVD.
  • Exploitation status from CISA’s Known Exploited Vulnerabilities catalog.
  • Exploit likelihood from FIRST’s Exploit Prediction Scoring System (EPSS), refreshed daily.
  • Explanations are written by Veriom from fixed templates over each record’s data, not by a person reviewing each CVE. Descriptions are quoted from the records as published.