CVE-2026-127174 is a vulnerability in pretix, rated medium (5.1 on CVSS 4.0).
Why this priority: Medium severity, with no exploitation signal.
Published · Updated · NVD status: Deferred
What it is
The record does not classify the weakness yet; the description below says what the reporter found.
How it is reached
An attacker can exploit it over the network, with an administrator account, and nobody has to click anything. Success also depends on conditions the attacker does not fully control.
What an attacker gains
A successful attack can read the data it protects. The damage can spread past the vulnerable component into others.
Is it being exploited?
There is no public report of exploitation yet.
What to do
- Upgrade pretix to a fixed version for your release line (2026.7.5, 2026.8.3, 2026.9.2).
- Until it is patched, review who holds accounts that can reach it.
Description from NVD
When changing the settings of a scheduled export, no permission checks are done to see whether the user making the change has access to the exporter after the change. This way, an attacker with access to change organizer settings and e.g. access to all orders could change the export to refer to gift cards instead, even if they do not have access to gift cards.
The fix for this is technically a breaking API change, since changing the export type of existing scheduled exports is no longer allowed, but we don't expect this to affect any typical API usage.
What this means for your architecture.
A CVE names a product. Whether it matters depends on where that product sits in your systems: what reaches it, which trust boundary it guards and what it can reach once compromised. Veriom maps your components, their relationships and your trust boundaries from your code, cloud and delivery evidence, so you can see where a component like this sits. The radar itself does not look at your systems.
Components it touches
- pretix. Start from where it runs and what it is connected to.
Trust boundaries in play
- Authenticated network access. An account is needed, so exposure follows who can sign in: customers, partners or staff.
- Isolation between components. The impact crosses out of the vulnerable component into others it should be isolated from.
Questions to answer about your own systems
- Where does pretix run in your systems, and at which version?
- Which of those instances can be reached from the internet or partner networks?
- What can it reach once compromised: which data stores, secrets and services?
Sources
- CVE records and CVSS scores from the NVD CVE API. This product uses the NVD API but is not endorsed or certified by the NVD.
- Exploitation status from CISA’s Known Exploited Vulnerabilities catalog.
- Exploit likelihood from FIRST’s Exploit Prediction Scoring System (EPSS), refreshed daily.
- Explanations are written by Veriom from fixed templates over each record’s data, not by a person reviewing each CVE. Descriptions are quoted from the records as published.