Skip to main content

CVE-2026-134338ArcadeData arcadedb incorrect authorization

Schedule itHigh8.7EPSS not scored yet

CVE-2026-134338 is a incorrect authorization in ArcadeData arcadedb, rated high (8.7 on CVSS 4.0).

Why this priority: High severity, with no exploitation signal yet.

Published · Updated · NVD status: Deferred

What it is

A permission check exists but gets the answer wrong for some callers.

How it is reached

An attacker can exploit it over the network, with an ordinary user account, and nobody has to click anything.

What an attacker gains

A successful attack can read the data it protects, change data or behaviour and take it offline. In practice, this kind of flaw lets an attacker reach data or actions their role should not allow.

Is it being exploited?

There is no public report of exploitation yet.

What to do

  1. Upgrade ArcadeData arcadedb to 26.11.1 or later.
  2. Until it is patched, review who holds accounts that can reach it.

Description from NVD

ArcadeDB 25.8.1 before 26.11.1 contains an incorrect authorization vulnerability because per-type ACLs are keyed by type name, renames are not propagated to the permission configuration, and requestAccessOnType allows unknown type names by default. Authenticated users holding only updateSchema can run ALTER TYPE NAME on a denied type to gain read, DELETE and TRUNCATE access, immediately for TIMESERIES types and after the next security rebuild for record-backed types.

What this means for your architecture.

A CVE names a product. Whether it matters depends on where that product sits in your systems: what reaches it, which trust boundary it guards and what it can reach once compromised. Veriom maps your components, their relationships and your trust boundaries from your code, cloud and delivery evidence, so you can see where a component like this sits. The radar itself does not look at your systems.

Components it touches

  • Permission checks in APIs and admin surfaces. The flaw sits between one role or tenant and another.
  • Multi-tenant services. The flaw sits between one role or tenant and another.

Trust boundaries in play

  • Authenticated network access. An account is needed, so exposure follows who can sign in: customers, partners or staff.
  • Between one role or tenant and another. An attacker who crosses it can reach data or actions their role should not allow.

Questions to answer about your own systems

  • Where does ArcadeData arcadedb run in your systems, and at which version?
  • Which of those instances can be reached from the internet or partner networks?
  • What can it reach once compromised: which data stores, secrets and services?

14-day free trial

Understand how your systems connect.

See your services, dependencies and trust boundaries in one place, with evidence from your connected environment.

Sources

  • CVE records and CVSS scores from the NVD CVE API. This product uses the NVD API but is not endorsed or certified by the NVD.
  • Exploitation status from CISA’s Known Exploited Vulnerabilities catalog.
  • Exploit likelihood from FIRST’s Exploit Prediction Scoring System (EPSS), refreshed daily.
  • Explanations are written by Veriom from fixed templates over each record’s data, not by a person reviewing each CVE. Descriptions are quoted from the records as published.