Skip to main content

CVE-2026-63017Subnet Solutions PowerSYSTEM Center 2020 incorrect authorization

Schedule itCritical9.4EPSS not scored yet

CVE-2026-63017 is a incorrect authorization in Subnet Solutions PowerSYSTEM Center 2020, rated critical (9.4 on CVSS 4.0).

Why this priority: Critical severity, with no exploitation signal yet.

Published · Updated · NVD status: Received

What it is

A permission check exists but gets the answer wrong for some callers.

How it is reached

An attacker can exploit it from the same local network segment, with an ordinary user account, and nobody has to click anything.

What an attacker gains

A successful attack can read the data it protects, change data or behaviour and take it offline. In practice, this kind of flaw lets an attacker reach data or actions their role should not allow. The damage can spread past the vulnerable component into others.

Is it being exploited?

There is no public report of exploitation yet.

What to do

  1. No fixed version is listed yet. Find every place Subnet Solutions PowerSYSTEM Center 2020 runs, watch the references for a fix, and plan a replacement if it is no longer supported.
  2. Segment the networks that can reach it.

Description from NVD

Incorrect authorization in PowerSYSTEM Center allows a low-privileged, authenticated user to access resources normally limited to administrators.

What this means for your architecture.

A CVE names a product. Whether it matters depends on where that product sits in your systems: what reaches it, which trust boundary it guards and what it can reach once compromised. Veriom maps your components, their relationships and your trust boundaries from your code, cloud and delivery evidence, so you can see where a component like this sits. The radar itself does not look at your systems.

Components it touches

  • Permission checks in APIs and admin surfaces. The flaw sits between one role or tenant and another.
  • Multi-tenant services. The flaw sits between one role or tenant and another.

Trust boundaries in play

  • Local network segment. The attacker must share a network segment with the target.
  • Isolation between components. The impact crosses out of the vulnerable component into others it should be isolated from.
  • Between one role or tenant and another. An attacker who crosses it can reach data or actions their role should not allow.

Questions to answer about your own systems

  • Where does Subnet Solutions PowerSYSTEM Center 2020 run in your systems, and at which version?
  • Which network segments can reach them?
  • What can it reach once compromised: which data stores, secrets and services?

Sources

  • CVE records and CVSS scores from the NVD CVE API. This product uses the NVD API but is not endorsed or certified by the NVD.
  • Exploitation status from CISA’s Known Exploited Vulnerabilities catalog.
  • Exploit likelihood from FIRST’s Exploit Prediction Scoring System (EPSS), refreshed daily.
  • Explanations are written by Veriom from fixed templates over each record’s data, not by a person reviewing each CVE. Descriptions are quoted from the records as published.