CVE-2026-63774Subnet Solutions PowerSYSTEM Center 2024 SQL injection

Schedule itCritical9.4EPSS not scored yet

CVE-2026-63774 is a SQL injection in Subnet Solutions PowerSYSTEM Center 2024, rated critical (9.4 on CVSS 4.0).

Why this priority: Critical severity, with no exploitation signal yet.

Published · Updated · NVD status: Received

What it is

Input is pasted into a database query, so an attacker can rewrite the query to read or change data.

How it is reached

An attacker can exploit it from the same local network segment, with an ordinary user account, and nobody has to click anything.

What an attacker gains

A successful attack can read the data it protects, change data or behaviour and take it offline. In practice, this kind of flaw lets an attacker read or change records in the data store behind the application. The damage can spread past the vulnerable component into others.

Is it being exploited?

There is no public report of exploitation yet.

What to do

  1. No fixed version is listed yet. Find every place Subnet Solutions PowerSYSTEM Center 2024 runs, watch the references for a fix, and plan a replacement if it is no longer supported.
  2. Segment the networks that can reach it.

Description from NVD

Insufficient input validation in the PowerSYSTEM Center report designer allows an authenticated user to execute unauthorized SQL commands.

What this means for your architecture.

A CVE names a product. Whether it matters depends on where that product sits in your systems: what reaches it, which trust boundary it guards and what it can reach once compromised. Veriom maps your components, their relationships and your trust boundaries from your code, cloud and delivery evidence, so you can see where a component like this sits. The radar itself does not look at your systems.

Components it touches

  • Services that build database or directory queries. The flaw sits between the application and its data store.
  • Databases. The flaw sits between the application and its data store.

Trust boundaries in play

  • Local network segment. The attacker must share a network segment with the target.
  • Isolation between components. The impact crosses out of the vulnerable component into others it should be isolated from.
  • Between the application and its data store. An attacker who crosses it can read or change records in the data store behind the application.

Questions to answer about your own systems

  • Where does Subnet Solutions PowerSYSTEM Center 2024 run in your systems, and at which version?
  • Which network segments can reach them?
  • What can it reach once compromised: which data stores, secrets and services?

Sources

  • CVE records and CVSS scores from the NVD CVE API. This product uses the NVD API but is not endorsed or certified by the NVD.
  • Exploitation status from CISA’s Known Exploited Vulnerabilities catalog.
  • Exploit likelihood from FIRST’s Exploit Prediction Scoring System (EPSS), refreshed daily.
  • Explanations are written by Veriom from fixed templates over each record’s data, not by a person reviewing each CVE. Descriptions are quoted from the records as published.