Skip to main content

CVE-2026-95378Zenitel VSFF6 path traversal

Schedule itHigh8.6EPSS not scored yet

CVE-2026-95378 is a path traversal in Zenitel VSFF6, rated high (8.6 on CVSS 4.0).

Why this priority: High severity, with no exploitation signal yet.

Published · Updated · NVD status: Received

What it is

A file name from the request can climb out of the intended folder with sequences like ../, reaching files the service never meant to expose. Files of dangerous types can be uploaded, and the server may run or serve them.

How it is reached

An attacker can exploit it over the network, with an administrator account, and nobody has to click anything.

What an attacker gains

A successful attack can read the data it protects, change data or behaviour and take it offline. In practice, this kind of flaw lets an attacker read or write files outside the folders the service meant to expose. The damage can spread past the vulnerable component into others.

Is it being exploited?

There is no public report of exploitation yet.

What to do

  1. Upgrade Zenitel VSFF6 to 10.1.3.0 or later. Other affected products have their own fixed versions on this page.
  2. Until it is patched, review who holds accounts that can reach it.

Description from NVD

Path traversal in the certificate upload endpoint (/api/certificate/upload) of the turbineweb web interface in Zenitel VSFF6, VSFF8, VSFF8MP, VSFF8MN, and VSFT devices with software versions from 10.0.3.0 before 10.1.3.0 allows authenticated administrators to write arbitrary files as root via a crafted filename parameter in a multipart upload request when the type field is set to any value other than https_certificate. In that case, both path validation and certificate content validation are skipped.

This can be escalated to arbitrary code execution as root, for example by overwriting startup scripts or planting SSH keys.

What this means for your architecture.

A CVE names a product. Whether it matters depends on where that product sits in your systems: what reaches it, which trust boundary it guards and what it can reach once compromised. Veriom maps your components, their relationships and your trust boundaries from your code, cloud and delivery evidence, so you can see where a component like this sits. The radar itself does not look at your systems.

Components it touches

  • File storage the service can read or write. The flaw sits between the application and the file system it can reach.
  • Upload endpoints and the storage behind them. The flaw sits between uploaded content and the servers that store or serve it.

Trust boundaries in play

  • Authenticated network access. An account is needed, so exposure follows who can sign in: customers, partners or staff.
  • Isolation between components. The impact crosses out of the vulnerable component into others it should be isolated from.
  • Between the application and the file system it can reach. An attacker who crosses it can read or write files outside the folders the service meant to expose.
  • Between uploaded content and the servers that store or serve it. An attacker who crosses it can place a file the server will run or serve to others.

Questions to answer about your own systems

  • Where does Zenitel VSFF6 run in your systems, and at which version?
  • Which of those instances can be reached from the internet or partner networks?
  • What can it reach once compromised: which data stores, secrets and services?

Sources

  • CVE records and CVSS scores from the NVD CVE API. This product uses the NVD API but is not endorsed or certified by the NVD.
  • Exploitation status from CISA’s Known Exploited Vulnerabilities catalog.
  • Exploit likelihood from FIRST’s Exploit Prediction Scoring System (EPSS), refreshed daily.
  • Explanations are written by Veriom from fixed templates over each record’s data, not by a person reviewing each CVE. Descriptions are quoted from the records as published.