CVE-2026-124760RT-Labs P-Net unchecked unusual condition
CVE-2026-124760 is a unchecked unusual condition in RT-Labs P-Net, rated low (2.3 on CVSS 4.0).
Why this priority: Low severity, with no exploitation signal.
Published · Updated · NVD status: Deferred
What it is
An unusual condition is not handled, leaving the software in an unsafe state.
How it is reached
An attacker can exploit it from the same local network segment, without an account, and nobody has to click anything. Success also depends on conditions the attacker does not fully control.
What an attacker gains
The direct impact is limited: partial access to data or a partial outage. In practice, this kind of flaw lets an attacker drive the component into behaviour its authors did not intend.
Is it being exploited?
There is no public report of exploitation yet.
What to do
- Upgrade RT-Labs P-Net to 1.0.4 or later.
- Segment the networks that can reach it.
Description from NVD
P-Net before 1.0.4 sets the alarm receiver state to waiting for confirmation before the data of a received alarm notification is parsed. If the parsing fails the state is not restored, and later alarm notifications of the same priority are discarded without acknowledge until the Application Relationship is released. The Application Relationship and the cyclic data exchange keep working. The attacker must be able to send an alarm notification in the context of an established Application Relationship and requires ADJACENT network access.
What this means for your architecture.
A CVE names a product. Whether it matters depends on where that product sits in your systems: what reaches it, which trust boundary it guards and what it can reach once compromised. Veriom maps your components, their relationships and your trust boundaries from your code, cloud and delivery evidence, so you can see where a component like this sits. The radar itself does not look at your systems.
Components it touches
- Interfaces that accept external input. The flaw sits at the input boundary of the affected component.
Trust boundaries in play
- Local network segment. The attacker must share a network segment with the target.
- At the input boundary of the affected component. An attacker who crosses it can drive the component into behaviour its authors did not intend.
Questions to answer about your own systems
- Where does RT-Labs P-Net run in your systems, and at which version?
- Which network segments can reach them?
- What can it reach once compromised: which data stores, secrets and services?
Sources
- CVE records and CVSS scores from the NVD CVE API. This product uses the NVD API but is not endorsed or certified by the NVD.
- Exploitation status from CISA’s Known Exploited Vulnerabilities catalog.
- Exploit likelihood from FIRST’s Exploit Prediction Scoring System (EPSS), refreshed daily.
- Explanations are written by Veriom from fixed templates over each record’s data, not by a person reviewing each CVE. Descriptions are quoted from the records as published.